Mitsubishi Air Conditioner Error Codes


Mitsubishi Electric Slim A-control

 

EA code - The indoor and / or outdoor unit is not correctly installed. It is necessary to check the interconnection, the electrical circuit. The chain is broken.

 

EB code - Rough installation faults, tripping of protection until tripping.

 

EU code - A startup error message appears for 5 minutes. Turn off the power, de-energize split system Mitsubishi Electric, get the batteries from the remote control. After 5 minutes, collect everything in reverse order.

 

In this case, all settings manually reset to zero and return to the factory settings.

 

e motor is observed.

Error codes for Mitsubishi Electric air conditioners of inverter type.

 

The connection is broken.

 

Code E6 - Signal about the connection error of the outdoor and (or) indoor units, as well as the sensor receiving the signals (signals are not accepted).

 

No signal with a short circuit.

 

Code E7 - Signal on connection error of external and (or) internal transmission blocks

 

No signal with a short circuit.

 

Code E8 - The signal about the error of the sensor operation. It is necessary to check the power supply to the sensor. The chain is broken.

 

Code E9 - Signal of an error in the operation of external and (or) internal connections between the units. The chain is broken. No signal.

 

Code E0 - No signal from the remote control (signal not received). On the remote control, you need to replace the batteries.

 

Code E3 - An error signal. The signal coming from the air conditioner PU is not formed correctly.

 

For correction, look at the EU Code.

 

Code E4 - Check interconnection, integrity of pressure sensors and temperature.

 

Code E5 - Check the mains voltage. The equipment may malfunction.

 

Code EF - Error M-NET, - no signal.

 

It is necessary to check the interconnection, poor connections or breakage of connections.

 

Code Ed - Violations in the signal generation sequence. Stepper searcher fails.

 

To correct the watch the EU Electric Code Mitsubishi Electric, reset the air conditioner settings, set the factory default settings.

 

Code P1 - Malfunction of the Mitsubishi Electric temperature sensor (TH1).

 

Inspect the sensor for mechanical integrity. The hermetic connection of the sensor is destroyed. Closing of the connecting cable and sensor due to the presence of dirt and moisture on them.

 

Code P2 - Indication of indoor unit freezing sensor.

 

Contamination of the indoor unit, insufficient air exchange, which is a consequence of the fact that the indoor unit is frozen.

 

The cause of frostbite is a lack of gas. Unplanned preventive maintenance of the conditioner is necessary.

 

Code P4 - Check drain, drainage, because there was a trigger of the sensor indicating the highest level in the bath. The drain is corked.

 

Code P5 - No draining. Idling operation of the drainage motor is observed.

Error codes for air conditioners Mitsubishi Heavy

E1-failure of the indoor PC board, the remote control is not connected correctly or is defective.

 

E2-Duplicate internal block addresses

 

E3 - incorrect address of outdoor unit

 

E5 - the outdoor unit control board is malfunctioning

 

E6 - Evaporator thermal sensor closed / broken

 

E7-indoor unit sensor closed / torn

 

E8 - evaporator overload or sensor defective

 

E9 - error of drain pump or float sensor

 

E10 - more than 16 indoor units are connected to the control panel

 

E11-more than one block is connected to the control panel when the address is busy

 

E12-address configuration error

 

E14 - incorrect connection settings master-slave (master-slave)

 

E16-indoor unit fan is faulty

 

E28 - the control panel sensor is faulty

 

E30 - Connection error of outdoor / indoor units

 

E31-Duplication, incorrect address settings

 

E32 - incorrect phase sequence or broken wire

 

E33 - compressor winding breakage

 

E34 - the phase L3 of the winding 52C is open

 

E35 -High condenser temperature or defective temperature sensor

 

E36 - Inadmissible deviation of outlet air temperature

 

E37 - Condenser Thermal Sensor Fault

 

E38 - Outside air temperature sensor faulty

 

E39 - the heat sensor of the discharge pipe is defective

 

E40 - the high pressure switch 63N1

 

E49-system stopped, low pressure or insufficient refrigerant

 

E52 - a failure in the 52C

 

E53 - the suction pipe thermistor is faulty

 

E54-Low pressure sensor connected

 

E55 - Compressor internal temperature thermistor faulty

 

E56 - power transistor thermistor faulty or broken

 

E57-insufficient refrigerant

 

E59 - the compressor does not start

 

E60 - compressor positioning error

 

E63 -Deviation of the indoor unit