WOLF Gas Boiler Error Codes


Error F2 - the supply fan is off. Most likely, there was a malfunction of the fan itself or its wiring. Check the wiring, and if necessary, replace or repair the fan.

 

Error F5 - The exhaust fan does not turn on. Most likely, there was a failure of the fan or its wiring. Check the wiring, and if necessary, replace or repair the fan.

 

Error F9 - the sensor that measures the supply air temperature is not working. It is possible to break the bypass, if the sensor is faultless. Defects the sensor itself or the air supply line to it. A break in the line from the sensor to the control board of the Wolf boiler. It is required to check all wiring and, if it is necessary to replace it.

 

Error F10 - the temperature gauge of the air leaving the system is defective. It is possible to break the bypass, with a serviceable meter. Defect of the meter itself or the air supply line to it. Break on the line from it to the board. It is required to check all wiring and, if it is necessary to replace it.

 

Error 1 - The maximum temperature of the coolant in the water supply line is exceeded. The water temperature is too high (the temperature limiter has tripped). The circulation of water is disturbed due to the fact that the heat exchanger is clogged. The pressure in the system does not match the recommended values. Malfunction of the water supply pump to the heating system (there may be a problem with the switching stages). It is required to press the reset button, and also to flush the heat exchanger.

 

Error 4 - no flame. When the burner starts, there is no flame. Check the gas supply. Perhaps just shut off the tap on its feed. There may be a breakdown of the ignition electrode itself or its wiring. Press the "reset" button. Check the ignition electrode.

 

Error 5 - during operation, the flame of the boiler Wolf turns off. This error is triggered if the unit dries out less than 15 seconds after the start of operation. It is possible that the amount of CO2 is exceeded. Check the ignition electrode and the wiring. Reset the fault by pressing the "reset" button.

 

Error 6 - the temperature relay has tripped. The water in the heating system or the return pipe exceeded the upper temperature limit. A pressure check in the system is required. Remove the air plugs. The flow speed to do more.

 

Error 7 - the temperature of the exhaust gases is too high. The temperature of the gases discharged from the system is higher than the set maximum. It is necessary to clean the burner and make sure that the pressure of the incoming gas is normal.

 

Error 8 - the gas valve is not working. Or breakdown of the valve itself, or from it comes a message about the problem. Make sure that the wiring is working. It may be necessary to replace the valve. It is also necessary to check the pressure on the valve.

 

Error 9 - the flap of the exhaust gases does not work. Damper is damaged or gives a fault signal. Check the cable and the damper itself.

 

Error 10 - failure of the temperature sensor in the supply line 2. The sensor itself or the wiring is damaged. Check and repair or replace the flow temperature sensor 2, check and repair the wiring.

 

Error 11 - Simulating the flame. Before the Wolf boiler was put into operation, the system detected a flame. Press the "reset" button. Ensure that the ionisation probe is operating correctly.

 

Error 12 - The temperature sensor in the supply line 1 is faulty. Check and repair or replace the flow temperature sensor 2, check and repair the wiring.

 

Error 13 - problems with the temperature sensor. The sensor is broken or damaged in its wiring. Check and, if necessary, replace the damaged part.

 

Error 14 - NTC sensor is not working. The DHW sensor or its wire is damaged. Check and, if necessary, repair / replace the sensor or cable.

 

Error 15 - problems with the outside temperature sensor. The DHW sensor or its wire is broken. Check and, if necessary, repair / replace part or cable.

 

Error 16 is the problem with the return temperature sensor. The return temperature sensor or its wire is damaged. Check and, if necessary, repair / install the new component or wiring.

 

Error 17 - Incorrect modulation current. The value of the modulation current is higher or lower than the set value range.


Error 20 - The gas valve VI is broken. The system receives a signal about the error of the gas valve VI. The gas valve is damaged, its replacement is required.

 

Error 21 - Breakdown of the gas valve V2. The gas valve does not work. Replace it.

 

Error 22 - The system lacks air. The differential pressure sensor can not be switched on. Reset the fault. It is necessary to check the silicone hoses that are suitable for the differential pressure switch. Also check the gas removal system (fan and chimney).

 

Error 23 - The differential pressure sensor is broken. Reset the fault. Check it and replace if necessary.

 

Error 24 - Broken fan. The fan does not reach the required rotation speed for its purging. First check the fan itself and its cables, then unlock the work.

 

Error 25 - Broken fan. The fan does not reach the required rotation speed for operation. First check the fan itself and its cables, then unlock the work.

 

Error 26 - Problem with the fan. The fan runs without stopping. Remove the lock from the fan. Check the fan itself and its wiring. You can remove it by pressing the "reset" button.

 

Error 27 - NTC sensor failure. There is a problem with the NTC sensor in the water heater.

 

Error 30 - Problems with CRC gas condensing boiler Wolf. The EP-ROM of the data group "Gas condensing boiler" does not work. Reboot the system by disconnecting the unit from the power source. If this does not work, then a replacement board is required.

 

Error 31 - Burner failure. Breakage of the EP-ROM of the "Burner" data group. Reboot the system by disconnecting the device from the power source. If this does not help, then the replacement of the control board is required.

 

Error 32 - There are problems with power supply 24 V. The control board needs to be replaced.

 

Error 33 - The factory setting failed. Internal boiler fault. Replacement of the electronic board is required.

 

Error 34 - BCC failed. A problem with the parametric plug. It is required to install a new plug.

 

Error 40 - Problems with the flow switch. There is no signal to turn the flow switch on and off. Make sure that the pressure in the system corresponds to the required pressure. Check the relay itself.

 

Error 42 - The pump responsible for condensate drainage is not working. Possible damage to the pump. There may be problems with the condensate drain line or the pump is not connected to the network. Check the listed modules. If you need to fix or replace.

 

Error 45 - Problems with the flow regulator. Perhaps the failure of the regulator itself or a communication failure. Check cable and regulator and repair / install new one.


Error 46 - Water sensor failure. The sensor is broken or the cable is damaged. Check. Replace part or wiring.

 

Error 52 - The operating time of the water heater has exceeded the maximum permissible value. The water heater is too hot. Check the pump and the boiler.

 

Error 60 - Fluctuations of the ionization current. There is no patency in the siphon or chimney. Clean and restore air supply and exhaust gas. Carry out an additional check of the control electrode.

 

Error 64 - Pulse sensor error. The pulse sensor of the solar control module has broken. Repair or replacement is required. It is also possible to disturb the flow in the system.

 

Error 70 - Problems with the temperature sensor of the mixing circuit, or the return temperature sensor (FV terminal) is damaged. Broken or damaged sensors. It is required to repair or replace them. You also need to check the wiring.

 

Error 71 - Breakdown of the temperature sensor of the water heater, storage tank, return water or boiler (terminal E1). Check the sensor against the wire. If necessary, replace.

 

Error 72 - the temperature sensor is damaged. Damage to the temperature sensor located on the return line on the control module of the solar system SM1 or the sensor of the control module of the solar system SM2 connected at the input E1. Verification is required. If necessary, install a new one.

 

Error 73 - The controller is not working properly. The sensor installed at the input of the ES sensor of the SM2 control module of the solar system does not work. It is necessary to test it and the wiring. Replacement with a new one.

 

Error 76 - Faulty cylinder regulator. Check it and the cable.

 

Error 78 - The collector sensor problem. Component does not work or the cable is damaged. Repair or replacement is required.

 

Error 79 - Sensor defect. The sensor input E1 of the boiler control system R1, R2, R3 or multi-function sensor input E2 of the mixer control module, cascade control module or collector regulator of the solar control module is not working. Requires repair or replacement on

new.

 

Error 80 - The outside temperature sensor on the accessory controller does not work. Repair or replacement.