Ariston logo

ARISTON Gas Boiler Troubleshooting

The azine boiler Ariston 24 ff produces an error SP3 (flame separation). It tries to ignite the flame, audible clicks of the electrodes. I have not looked at the camera yet, but it sounds similar to sounds that the flame ignites and is immediately extinguished. He will help to repeat these attempts 10-20 times. The error blinks on the display.

 

Remove the outer panel (2 bolts). Internal panel (2 clamps). Combustion chamber (2 bolts). Put a piece of paper on the nozzles so they do not get clogged, and clean the heater element from any dust with a toothbrush from above. Vacuum as could injectors from below. Strip the ends of the spark-generating electrodes with fine sandpaper. At the same time, the flame control electrode (just in case). Turn on, test, then close the combustion chamber and hang the panels back. The result: the device works without failures. Heating and water heat up without problems.

 

Ariston Egis Plus wall-mounted boiler. The last 3-4 years, the problem is increasing, it happens more and more often. The apparatus worked without an external temperature regulator at low temperatures. So, if you try to start heating quickly, there are two relays, from which the ignition unit (control) is controlled, there is no spark, no flame. The device instantly gives out an error 5P3, thinks for a while and then again flips the relay, again gives an error, and so it goes in a circle, since 10th a spark can go, and work will go on. If you go to the menu (on the screen number 2), the ignition is normal, the unit works without problems, and so on until you are in the menu. Only you leave the menu - error 5P3. Disconnecting the flame sensor during boiler operation (in the menu) immediately leads to 5p3 and a normal ignition attempt with a spark. If you exit the menu - immediately 5P3, the flame goes out, and it flips the relay without a spark. The board is old, version 4V3. The error is periodic, it happens, it works for weeks, and sometimes it shows it all day long.

 


Double-circuit boiler Ariston with a closed combustion chamber. After a prolonged interruption in the operation, when the appliance is switched on, the burner will run for a short time, then it will turn off and an error message 104 (circulation disturbance) will be output. The pipe leading to the heating system does not heat up, i.e. there is really no water circulation in the system. I checked the flow of the system in both directions - everything is fine, i.e., most likely, not clogging. Although the test produced water under pressure from the central water supply system. After the tap of the water supply was shut off, with the drain valve open, the system itself was released from the excess pressure completely. Therefore, I believe that the problem is not clogging. But I'm not an expert, so I can be wrong. Suspicion falls on the pump. Tell me, how can I tell if he broke down? The noise can not be determined, because the fan also blows, which supplies air to the combustion chamber. Or maybe it's not in the pump?

 

It looks like sticking a pump. You just need to scroll with a screwdriver. Unscrew the plug on the pump, rotate the rotor.

 

If the appliance knocks an error on the chimney - open its protective covers (in turbo versions - 2 pcs., In the version of a conventional chimney - 1 pc.). This will make the air intake from the room. 2) We check the discharge pipe for the presence of ice, clean it, and if it is not possible to get the ice and clean it, then leave the unit to work in an open state. If fault 501 or flame (flame separation): Check if gas is flowing into the house, whether the cooker is working. The reducer could be frozen at the entrance to the house.


Error 104 is insufficient circulation. The reason can be either in the relay or in the pump itself. To make sure that the pump rotates, unscrew the screw on the head, turn on the unit in the "Purge" mode by pressing the ESC button for more than 5 seconds. In this mode, the pump must rotate, but without ignition of the flame. Visually determine if the pump shaft rotates, you can go there with a screwdriver, immediately you will feel if there is rotation or not. In the "purge" mode, the pump runs cyclically. Observe, is there a pump start after every pause or not? The pump is controlled by two relays - one supplies power to the motor, the other just closes or opens the pump speed control circuit. The last check is easy, just close the contacts, so you force one of the speeds on and remove the relay from the circuit. If it is defective, the pump will start to rotate steadily, and will circulate.

 

On the boiler, error 108 is being written. How can I fix it?

 

The pressure in the heating system should be raised to the required level.

 

When you open a tap of hot water, somewhere in about 20 seconds, gives an error of 109 and then goes cold. What is the problem?

 

The reason is poor circulation or failure of temperature sensors. There was such a problem, the spring in the actuator of the three-way valve burst, it changes on its own.

 

Wall-mounted gas boiler Ariston constantly gives error 101. What is it connected with?

 

Something happened to the traction sensor apparently, check it or replace it.

 

The boiler Ariston, with the use of hot water is turned off - ERR 105. The pressure of water and gas is normal, with the work of the heater is no problem. How to start using hot water, either immediately error 105, or after 10-15 minutes. Once visually visually how everything is going on - 101 (overheating) for a short time, and then 105 at once. I tried to lower the water temperature, change the pressure - it does not help.

 

Most likely, the problem is in the clogged secondary heat exchanger. Remove and rinse with a special descaling solution.

 

When turned on, gives an error of 307. I tried with two different display boards. Reset is reset, but again jumps out.

 

There was such a problem. I tried the firmware, the error was gone, but the interface board does not adjust the temperature setting for either heating or hot water. Therefore, only a replacement board.

 

Gas boiler Ariston 24, the scoreboard flashes error 201. The device itself is working, the water temperature is regulated by a manual switch. What is the reason and how to fix it? Installed his master and overheated, including the auto mode, and there is no external air temperature sensor.

 

Most likely, there is a problem with the NTC sensor.

 

Problem Algorithm: The pump starts. The turbine turns on. Gas is being served. A spark is being given. After that, the display shows error SP3. And so he tries to ignite 10-15 times and either ignites himself, or it is necessary to open the hot water tap to maximum, and once on the 5th it is started.

 

Replace or adjust the exhaust gas manostat / pressure switch.