Panasonic Air Conditioner Error Codes


When Panasonic systems appear in system diagrams, they are blocked, and the chronometer's LED light will pulsate on the front dial.

 

If this climate device with a multisplit supply system, then it is necessary to decode the code abbreviations of faults in a separate order.

 

(H00) - No violations found

 

(H11) - There is no interaction between the outdoor and plug-in unit, the management boards do not work

 

(Н12) - violation of parameters of power characteristics between the external and plug-in unit

 

(Н14) - the detector of giving of air weights is faulty

 

(Н15) - violation of the operation mode of the temperature detector of the compressor unit

 

(H16) - low current consumption by the outdoor unit - lack of cooler, open circuit, failure of the external module board, malfunction of the IPM device of the power type

 

(Н17) - violation of the operating mode of the temperature detector on the suction side of the cooler

 

(H19) - violation of the operating mode of the fan motor of the built-in unit - possible objects: power plant, board or wiring connector.

 

(H21) - the drainage system or the float type detector is defective

 

(Н23) - the detector of a temperature mode of the evaporator N1 is faulty

 

(Н24) - the detector of a temperature mode of the evaporator N2 is faulty

 

(Н25) - the block of distribution of ionization radiation or the built-in unit board are subject to repair

 

(Н26) - device - ionizer

 

(Н27) - street temperature detector is defective

 

(Н28) - the detector of a temperature mode of condenser N1 is faulty

 

(Н30) - the detector of a temperature mode of a delivery is faulty

 

(Н32) - the detector of a temperature mode on an output cascade of the condenser is faulty

 

(Н33) -accuracy of connecting blocks

 

(H34) -the detector of the temperature regime of the cooling system is defective

 

(H35) -sorption of the drainage system, pump defect (R motor windings - about 0.2 KΩ)

 

(Н36) - the detector of a temperature mode of a tube of gas submission of the external block is faulty

 

(Н37) - the detector of a temperature mode the gauge of a tube for delivery of a liquid of the external block is faulty

 

(Н38) - violation of compliance of external and built-in units

 

(H39) - violation of the mode of connecting the wires and circuits of multi-split systems, the defect of the solenoid valve of the external unit

 

(H41) - violation of the mode of connecting the wires and pipelines of the cooler

 

(Н50) - malfunction of the fan motor or its board

 

(H51) - clogging of the output system

 

(H52) - defect of the cut-off system

 

(Н58) - defect of the block system "Patrol Sensor"

 

(H64) - high-pressure detector detector defect

 

(H97) - compressor motor defect, integrated circuit board

 

(Н98) - violation of the protective functions of the built-in unit from overheating in the mode of thermal radiation (high pressure), weak heat radiation from the heat exchanger of the built-in unit, defect of the detector


(Н99) - the device - the evaporator was covered with ice

 

(F11) - the operating parameters of the 4-way valve

 

(F17) - formation of ice on the built-in unit in standby mode, the error appears on the frozen block

 

(F90) - various defects of the compressor windings, defect in the inverter board

 

(F91) - the violation of the operating parameters of the refrigeration system circuit, the use of protective functions for low pressure

 

(F93) - various defects of the compressor windings, defect of the inverter board

 

(F94) -the need to introduce protective functions due to increased injection

 

Pressures

 

(F95) - Excess heating temperature of the external unit heat exchanger

 

(F96) - excess of temperature of heating of the engine compartment, for multi-split systems - activation of a temperature sensor

 

(F97) - the compressor's heating temperature is exceeded

 

(F98) - introduction of protective functions for the total consumed electricity

 

(F99) - the error of the DC protective system, possible situations: compressor failure, defect of the transistor system, current detector of the outdoor unit board, low resistance of compressor windings.