CODES OF ERRORS OF GREE AIR CONDITIONERS

  

Error code display Indicator Flashing indicators on the indoor unit Errors in operation or tripping of protection

E1 Operation indicator Flashes once every 3 seconds Compressor protection against high pressure

E2 Flashing 2 times every 3 seconds Protection against freezing of indoor unit

E3 Flashing 3 times every 3 seconds Compressor protection against low pressure

E4 Flashing 4 times every 3 seconds High temperature protection on the compressor discharge pipe

E5 Flashing 5 times every 3 seconds Protecting the compressor or system from overloads

E6 Flashes 6 times every 3 seconds. Connection fault (commutation). Absence of supply and signal cables (absence of phase)

E7 Flashing 7 times every 3 seconds Contrast of the set mode

E8 Blinks 8 times every 3 seconds. Evaporator protection against overheating. The motor protection of the indoor unit has tripped.

E9 Flashing 9 times every 3 seconds Cold air supply protection in heating mode

E0 Flashing 10 times every 3 seconds Protection of the frequency controller at low starting voltage

H6 Flashing 11 times every 3 seconds No feedback signal from the fan motor of the indoor unit

F0 Temperature sensor fault

F1 Cold running indicator Flashes once every 3 seconds Temperature sensor fault on the evaporator

F2 Flashes 2 times every 3 seconds Condenser temperature sensor fault

F3 Blinks 3 times every 3 seconds Ambient air sensor fault in outdoor unit

F4 Flashing 4 times every 3 seconds Temperature pump fault

F5 Flashing 5 times every 3 seconds Malfunction of the sensor on the discharge pipe of the compressor

F6 Flashing 6 times every 3 seconds Condenser overheating at low speed in cooling mode (Inverter)

F7 Flashing 7 times every 3 seconds Protecting against oil carrying from the compressor (Inverter)

F8 Blinks 8 times every 3 seconds Compressor or system protection against overload at low speed (Inverter)

F9 Flashing 9 times every 3 seconds Compressor protection at high discharge and low speed (Inverter)

FF Phase monitor malfunction, no power supply to one phase

H1 Heat-on indicator Flashing once every 3 seconds Defrosting

H2 Flashing 2 times every 3 seconds Protection of electrostatic filter

H3 Flashing 3 times every 3 seconds Protecting the compressor against overheating

H4 Flashes 4 times every 3 seconds System malfunction

H5 Blinks 5 times every 3 seconds IPM block protection

H7 Flashes 6 times every 3 seconds Compressor fault (DC Inverter)

H8 Flashing 7 times every 3 seconds Drainage overflow protection

H9 Flashes 8 times every 3 seconds Faulty electric heater

H0 Flashing 9 times every 3 seconds Evaporator protection against overheating (Inverter)

FA Protection of evaporator or condenser against overheating at low speed (Inverter)

FH Evaporator frost protection (Inverter)


On the air conditioners and split systems Gree, not so many sensors of the protection system, everything is simplified and unified.

Self-diagnosis of air conditioners Gree

What is the explanation for the philistine?

The explanation is simple. On conditioners and split systems Gree, not so many sensors of the protection system. Those. Everything is simplified.

The internal self-diagnosis of Gree conditioners is unified and almost identical in error positions of inexpensive air conditioners, for example such as Pioneer, General Climate, Lessar and others.

You will laugh, but for example, the catalog of air conditioners Supra, did not even change the name of the outdoor unit, maybe you do not have enough skills in photoshop, maybe you did not find it necessary.

In a word, how are the Supra air conditioners certified in Russia? For me, a mystery. Catalog of Supra !! In fact. Heh ...

Self-diagnosis of air conditioners Gree is, -

High pressure protection,

Protection against freezing of the evaporator,

Compressor overload protection,

Errors in switching air conditioner during installation, confusing wires,

And the errors of the temperature sensors of the evaporator and condenser.

Everything, do not agree much. Gree, as an air conditioner, is simple functionally, so there are not so many error codes.

There are disadvantages of this simplification, these are weak varistors of the control board, insufficient smoothing

Gree, as an air conditioner, is simple functionally, so there are not so many error codes.

Error codes table, continued.

Currents during voltage surges. Trifle, but it must be borne in mind when repairing air conditioners Gree and their counterparts.

Example: country cottage. The owners leaving the dacha usually de-energize the building with a common switch.

Those. They put out everything and calmed down. We arrived ... Turned on the light of the same knife, and air conditioning, refrigerator, or other household appliances does not work. Why? The answer is simple.

When the power is turned on with the load, current and voltage surges occur.

Varistors, smoothing voltage surges do not cope with the current load and burn out, burn well with smoke and soot, in the absence of a protective shell, usually together with the fuse of the control board of the indoor unit of the split system.

There are "specialists" who use the wire when fusing the fuse. Can I do this? It is possible, but then, apart from the varistors, the control board, the fan of the indoor unit, will also burn out, and ... it raced right up to the windings of the compressor of the outdoor unit of the air conditioner.

Fireworks at the cottage. - Expensive repair.

Troubleshooting and breakdowns of the air conditioner, we as usual start with:

 

- failure of the refrigeration circuit,

- malfunction of the electrical part, the electrical system. Power and air conditioning control.

A source:

Map of errors, mapping. Primary system diagnostics.

GREE Air conditioners of semi-industrial, industrial use, - error codes.

 

Error code = E1

Compressor, pressure surge (sound signal).

Error code = E2

Defective coil

Error code = E3

The compressor of the air conditioner was activated under low pressure (sound signal)

Error code = F0

Defective room temperature sensor.

Error code = F1

Wrong sensor resistance.

Error code = F2

The temperature sensor of the outdoor unit of the air conditioner was activated.

Error code = F3

The temperature sensor circuit is open.

GREE Split Air Conditioner Error Code ...

The cause of the malfunction, - the refrigerant system is a high degree of protection, - pressure.

Code = E1

LED start of the air conditioner = the Gree LED flashes 1 time.

Indicator, - cooling =

Heating indicator =

The cause of Gree faults is frost protection.

Code = E2

LED start the air conditioner = LED flashes 2 times.

Indicator, - cooling =

Heating indicator =

The cause of the malfunction is the high-temperature exhaust exhaust compressor.

Code = E4

LED start the air conditioner = blink 4 times

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - AC overload protection

Code = E5

LED start the air conditioner = LED flashes 5 times

Indicator, - cooling =

Heating indicator =

The cause of the malfunction is the communication failure between the indoor unit of the air conditioner and the outdoor unit of the split system.

Code = E6

LED starts the air conditioner Gree = flashes 6 times

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Anti-high temperature protection

Code = E8

LED start the air conditioner = blink 8 times

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - There is no feedback from the internal fan motor

Code = H6

LED start the air conditioner = flashes 11 times

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Jumper header defective

Code = C5

LED start the air conditioner = flashes 15 times

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Closed ambient sensor open, no contact or short circuit

Code = F1

Indicator, - cooling = LED flashing 1 time

Heating indicator =

Name malfunction or sensor failure = Indoor tube open, no contact or short circuit

Code = F2

LED start the air conditioning =

Indicator, - cooling = LED flashing 2 times

Heating indicator =

The cause of the malfunction, - the outdoor ambient sensor is open, there is no contact or short circuit

Code = F3

LED start the air conditioning =

Indicator, - cooling = LED flashing 3 times

Heating indicator =

Cause of malfunction, - External tube sensor open, no contact or short circuit

Code = F4

LED start the air conditioning =

Indicator, - cooling = blinking 4 times

Heating indicator =

Name = Fault or malfunction of the exhaust sensor open, no contact or short circuit

Code = F5

LED start the air conditioning =

Indicator, - cooling = LED flashing 5 times

Heating indicator =

Cause of failure, - Overload / frequency reduction

Code = F6

LED start the air conditioning =

Indicator, - cooling = Blink 6 times

Heating indicator =

Cause of malfunction, - For limiting the current / output frequency

Code = F8

LED start the air conditioning =

Indicator, - cooling = blinking 8 times

Heating indicator =

Cause of malfunction, - High exhaust gas temperature limit / frequency reduction

Code = F9

LED start the air conditioning =

Indicator, - cooling flash = 9 times

Heating indicator =

Fault cause, - Overvoltage protection for Roux

Code = PH

LED start the air conditioning =

Indicator, - cooling = flashing 11 times

Heating indicator =

The cause of the malfunction is the alternating detection current of the defective circuit

Code = U5

LED start the air conditioning =

Indicator, - cooling = flashing 13 times

Heating indicator =

Cause of malfunction, - Compressor reverse protection

Code = U4

LED start the air conditioning =

Indicator, - cooling = flashing 14 times

Heating indicator =

The cause of the malfunction, - Behind the phase current compressor

Code = P5

LED start the air conditioning =

Indicator, - cooling = flashing 15 times

Heating indicator =

The cause of the malfunction is the entrance of the malfucntion with a probe tube

Code = b5

LED start the air conditioning =

Indicator, - cooling = flashing 19 times

Heating indicator =

Cause of malfunction, - The open DC fan motor is defective.

Code = L3

LED start the air conditioning =

Indicator, - cooling = flashing 21 times

Heating indicator =

Cause of malfunction, - Output malfunction or tube sensor failure

Code = b7

LED start the air conditioning =

Indicator, - cooling = blinking 22 times

Heating indicator =

Cause of malfunction, - The overload sensor is faulty.

Code = FE

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Defrost

Code = H1

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = LED flashes 1 time

The cause of the malfunction is static dust protection

Code = H2

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = LED flashes 2 times

Cause of malfunction, - Overload protection

Code = H3

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = LED flashes 3 times

Cause of malfunction, - System abnormal protection

Code = H4

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 4 times

The cause of the malfunction, - IPM protection

Code = H5

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = LED flashes 5 times

Cause of malfunction, - PFC protection

Code = HC

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = blinks 6 times

Cause of malfunction, - Step protection compressor

Code = H7

LED start the air conditioning =

Indicator, - cooling =

Heating indicator flash = 7 times

Cause of malfunction, - Heating against high-frequency drop in temperature

Code = HO

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 10 times

Cause of failure, - Run failure

Code = Lc

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 11 times

Cause of malfunction, - Phase failure protection compressor

Code = U2

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 12 times

The cause of the malfunction, - The phase current compressor is defective. Detection circuits

Code = U1

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = blinks 13 times

Cause of malfunction, - Demagnetization compressor protection

Code = HE

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 14 times

Cause of malfunction, - EEPROM boot failed.

Code = EE

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 15 times

The cause of the malfunction is a communication failure between the motherboard and the board driver

Code = P6

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 16 times

Cause of malfunction, - Charge failure capacitor

Code = PU

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 17 times

The cause of the malfunction, - the ИПМ of the sensor circuit is defective.

Code = P7

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 18 times

The cause of the malfunction is the high-temperature protection IPM

Code = P8

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = blinks 19 times

Cause of malfunction, - PN voltage drop protection

Code = U3

LED start the air conditioning =

Indicator, - cooling = flashing 20 times

Heating indicator =

Cause of malfunction, - low voltage protection PN

Code = PL

LED start the air conditioning =

Indicator, - cooling =

Heating indicator = flashes 21 times

Cause of malfunction, - Current detection circuit is defective. Or fault or sensor fault current

Code = Pc

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of failure, - Phase failure protection compressor

Code = Ld

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Compressor or blocked rotary protection

Code = LE

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - ИПМ more than temperature limit / frequency reduction

Code = EU

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

The cause of the malfunction, - the 4-way turn valve is abnormal

Code = U7

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - switch off the exhaust gas temperature sensor

Code = U8

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - AC zero fault detection voltage

Code = U9

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Over the tube temperature drop frequency

Code = FA

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =

Cause of malfunction, - Anti-freeze limit / decrease frequency

Code = FH

LED start the air conditioning =

Indicator, - cooling =

Heating indicator =