BAXI  ECO 280 i
Baxi ECO Compact 1.14 F

Baxi Gas Boiler Error Codes

Error E01 - the flame sensor is responsible for this error

 Lack of air

 Defective gas valve

 No gas

 Defective, contaminated or incorrectly installed flame monitor

 Loosely attached coaxial chimney

 Defective ignition system

 

Error E02 (02E) - overheating safety thermostat

 Insufficient circulation of coolant through the primary heat exchanger

 Overheating of water in the main circuit

 The absence of a good contact between the temperature sensor of the heating circuit and the coolant

 No contact between board and overheating thermostat

 Defective thermostat overheating

 

Error E03 (03E) - the diagnosis of this error is answered by a pneumatic relay (thrust sensor)

 Fault pneumatic relay - traction sensor

 No contact between board and fan

 The connection of the pipes to the pneumatic relay

 Water has entered the pipes connecting the pneumatic relay with the venturi device

 Chimney or chimney flue gasification

 Faulty fan

 Exceeded the maximum length of the chimneys

 

Error E10 (10E) - minimum pressure switch

 Defective minimum pressure switch for heating circuit

 Insufficient water pressure in the heating circuit

 There is no contact between the board and the minimum pressure switch of the heating circuit

 

Error E06 (06E) - DHW temperature sensor

 Defective electronic board

 The DHW temperature sensor is defective

 There is no contact between the board and the DHW temperature sensor

 

Error E05 (05E) - heating circuit temperature sensor

Defective electronic board

Defective heating circuit temperature sensor

There is no contact between the board and the temperature sensor of the heating circuit

 

Error E04 (04E) - Flame monitoring electrode

Defective electronic board

Bad contact of the flame monitoring electrode

Unstable voltage in the network

The flame monitoring electrode is dirty

Incorrect work of the chimney


Error E25 (25E) - the temperature sensor of the heating circuit

The heating system is inflated

Defective heating circuit temperature sensor

Pump blockage possible

 

Error E25 (25E) - DHW and DHW temperature sensor

Presence of scale in bithermal heat exchange. It is necessary to replace or flush the heat exchanger

 

Error E35 (35E) - Flame monitoring electrode

Moisture on the electronic board of the boiler

The presence of a flame after the burner is switched off - a parasitic flame

 

Error E96 (96E) - an electronic board

Low voltage in the mains, it is necessary to install a voltage regulator